I'm not sure if it's handy homeowners or negligent contractors that are responsible, but I find the same installation defects on water softeners over and over again.  The installation instructions for water softeners are pretty much the same for all the different manufacturers, so the information I'm giving here should apply to just about any water softener.

Missing ground clamp

All of the metallic water distribution pipes in the home are supposed to be bonded; in other words, they're all supposed to be able to touch each other.  If the water pipes in the home weren't bonded, what would happen if an energized (aka 'hot', aka 'ungrounded') wire came in contact with one of the pipes?  All of the plumbing fixtures and other pipes that were connected would become silently energized.  When everything is properly bonded and there is a proper ground jumper at the water meter, this can't happen.

I find this bonding compromised by a plastic by-pass valve at nearly half of the water softeners I see.  If the water softener manufacturer provides a plastic by-pass valve, they will also provide a ground clamp that needs to be installed on the water pipes coming in to and going out of the water softener.

Ground clamp diagram

If you live in Saint Louis Park and you don't have this installed when it's time to sell your home, the city inspector will require repair of this as part of their Point of Sale inspection program.  If you don't have the clamp, don't worry; you can achieve the same thing with a pair of ground clamps attached to the water pipes and a bare copper wire running between them.

Ground clamp
ground clamp

Improper drain hose

The drain hose that comes from the water softener needs to terminate in a manner that won't create a potential cross-connection between the potable water and anything else... such as sewer water.  This is usually achieved with an air gap; this is just a literal gap between the end of the discharge pipe and the drain receptor, whether it's a floor drain, standpipe, or laundry sink.  The only problem with the diagram below, which is what one of the water softener manufacturers includes in their installation manual, is that water will shoot all over the place.  When water softeners discharge water, the water flows fast.  It doesn't dribble out.

air gap at water softener drain

The photo below is an example of an air gap at the floor drain.  Even if the floor drain were to back up with sewer water, the water wouldn't come in contact with the end of the discharge hose.  Also, note that the cover for the floor drain has been cut out a little bit; if this wasn't done, the discharge from the water softener would probably splash water all over the place.

Water softener discharge at floor drain
Water softener discharge at floor drain

Softened water provided to the outside faucets

While this isn't technically a defect, it's bad practice to run softened water to the outside faucets.  Lawns and plants don't need softened water, and this is a tremendous waste of softened water.  Any time a water softener is installed, the water supply pipes for the outside faucets should be connected upstream of the water softener.

It's also standard practice to connect the cold water for the kitchen sink upstream of the water softener.  The reason for this is that softened water will have a higher sodium content - but probably not enough to make much of a difference, according to the Mayo Clinic web site.

In the photo below, you can see that all the water for the house passes through the water softener; this is a wasteful installation that should be corrected.  Because this was an unfinished room, it would be quite simple to run un-softened water to the outside faucets and kitchen sink.

Softened water to entire house

Powered by an extension cord

This is probably the biggest "no duh" defect that I find with water softeners.  Everyone knows that extension cords aren't supposed to be used as a substitute for permanent wiring.  If an outlet is needed, it should be installed by an electrician.

That concludes my list of the most common water softener installation defects.  While I'm on the topic of water softeners though, here's one more piece of information; this list gives the water hardness for most cities in the Twin Cities metro area.  I keep this list with me, and use it as a reference whenever a clients asks me about the water hardness is their city.   Water Hardness List


Reuben Saltzman, Structure Tech Home Inspections

        

Comment balloon 12 commentsReuben Saltzman • July 19 2011 05:03AM
Water Softener Installation Defects
share
I'm not sure if it's handy homeowners or negligent contractors that are responsible, but I find the same installation defects on water softeners over and over again. The installation instructions for water softeners are pretty much the… more
Vacant Houses Don't Have More Radon
share
As a Minnesota home inspector who does a lot of radon testing, I hear a lot of myths about radon being repeated over and over again. I've actually heard other home inspectors perpetuate a few of these radon myths as well. Myth: vacant… more
What will happen when your sump pump fails?
share
Most houses with sump pumps rely on the pumps to keep the basement from flooding. When a big rain storm comes through, the sump pump will really be needed… and that's also the time that the power to a neighborhood is most likely… more
Does the bath tub overflow leak? There's only one way to find out.
share
Many years ago, I learned about a bath tub leak that I never caught during my home inspection. The seller didn't have any children and didn't take baths, so they never knew about the problem with the bath tub drain. I did my standard… more
Houses never need cosmetic updates
share
Today is going to be a long day. As I sit here writing this blog post, it's 4:55 am and I just finished doing a little research on the house that I'll be inspecting at 9:00 am. The online listing for this property says it has lots of… more
Why municipal inspectors wear blinders
share
I've taken many building code classes that were taught by the Building Official for the City of New Hope, Roger Axel. He's a fantastic teacher. In his classes, I remember him repeatedly telling us to take off the blinders; what he… more
Trapping Your Condensate
share
In approximately 99. 2% of the houses that I inspect, there's a 3/4" hole in the air conditioner ductwork that lets air blow out where it shouldn't. Can you guess what it is? Here's a clue. Do you see it? It's… more
What A Peer Review Taught Me: My Home Inspection Reports Need Work
share
I've always been proud of the home inspection reports that I produce, but a recent peer review of my reports turned my pride to embarrassment. I swapped home inspection reports with a couple of home inspectors in different parts of the country for… more
Double Tapped Neutrals: This Isn't A New Rule
share
While I try to make most of my blog posts somewhat generic and appealing to most, this one ain't that. This post is about a very specific electrical defect that I frequently run across, and I'm writing this post so I can give my clients a… more
Should You Drain Your Water Heater?
share
I've read a lot of water heater installation manuals, and they all give the same advice on water heater maintenance, but most people don't do any type of maintenance on their water heaters, period. Today I'm going to go over the… more