A Common Problem With Roof Caps For Bath Fans

Stains in AtticI start every home inspection by giving myself a quick tour of the inside of the house to get an idea of what I need to be looking for while inspecting the exterior.  While doing my brief initial walk-thru of the interior, I also turn on everything that removes air from the house, such as bath fans, kitchen exhaust fans, and dryers.  I do this to create negative pressure in the house so I can later make sure that all of the fuel burning appliances still draft properly, and to make sure that all of the fans exhaust the way they're supposed to. 

As I turn the fans on in the home, I make a mental note of how many fans I've turned on, and I account for each exhaust while inspecting the exterior.  I've caught a ridiculous amount of bathroom exhaust fans there were vented in to attics or finished floor / ceiling spaces by doing this.  This is also a way for me to check to see that the fans are actually exhausting air, not just making a lot of noise.

I check the operation of bath fans by just putting my hand at the exhaust and making sure air is blowing out - after first checking for wasp nests, of course.  About one-third of the fans that are supposed to be exhausting through the roof are exhausting to a cap with a backdraft damper that is stuck closed, which causes a good portion of the warm, moist air to exhaust in to the attic space (pictured above).  Most of the dampers that I see are made by Broan, so I'll be talking about their specific roof cap.

Most roof caps for bath fan exhausts have a light aluminum backdraft damper which rests on a sealant strip, which is basically a foam piece of weatherstripping.  This sealant strip is installed to keep cold air from coming in, and according to a Broan customer service, it also "helps to prevent unbearable metal on metal chatter."  I'd have to agree!  Unfortunately, when the sealant strip gets hot from the sun beating on the cap all day, it gets sticky.  Eventually, the damper gets completely stuck to the sealant strip, which prevents the damper from opening.  This is what causes the black staining in the attic that you see pictured above. 

When I find this defect, I usually take my awl and pry the damper open, which allows the damper to open and close freely again... until the next hot day.  Broan received so many complaints about these dampers getting stuck that they changed the material that is used for the sealant strip in 2006.  Now the sealant strips are made of polyester, and they don't get stuck any more.  If you own a house with older roof caps, you can order a replacement damper and sealant strip from Broan by calling 800-558-1711, part # s7017696.  Click here for damper replacement instructions - they're listed under the Maintenance section.  I'll be recommending this to a lot of my customers.

Reuben Saltzman, Structure Tech Home Inspections - Email - Minnesota Home Inspector

Special thanks to Judi Weber at Broan for contributing information to help write this.

Reuben Saltzman, Structure Tech Home Inspections

        

Comment balloon 4 commentsReuben Saltzman • May 26 2009 06:17AM

Comments

I would also suggest switching to a different brand of bath fan, such as Nutone, which seems to be a lot more reliable. The dampers are located out of the weather next to the fan body, and I have never heard of one getting stuck. :))

 

Posted by Kevin Corsa, H.I.S. Home Inspections, Stark & Summit County, OH Home Inspector (H.I.S. Home Inspections (Summit, Stark Counties)) over 9 years ago

Is this the product you're talking about?  http://www.nutone.com/product-detail.asp?ProductID=11371

It looks to be identical to the Broan roof cap.  What's the difference?

Posted by Reuben Saltzman, Delivering the Unbiased Truth. (Structure Tech Home Inspections) over 9 years ago

In my experience the Panasonic is the quietest---even though other brands have quiet versions.  Also almost all have backdraft dampers at the unit itself but it is still required by energy code to have them in the cap at the exterior point of termination as well----at least in jurisdictions in my area (Washington Energy Code).  Is it different in you guy's areas?

Posted by Charles Buell, Seattle Home Inspector (Charles Buell Inspections Inc.) over 9 years ago

Charles - I agree, Panasonics are the quietest I've heard too.  Yes, we also require backdraft dampers here in Minnesota... of course :)

Posted by Reuben Saltzman, Delivering the Unbiased Truth. (Structure Tech Home Inspections) over 9 years ago