Reuben's Home Inspection Blog

head_left_image

Frost Heaved Decks and How to Avoid Them

One of the most common problems with decks in Minnesota is frost heave. Today I’ll explain how this works, why it matters, and what steps can be taken to help prevent damage from frost heave when building a deck.

How Frost Heave Works

When expansive soils freeze and expand, the earth rises. Wikipedia has a nice illustration of how this works, shown below.

Frost Heave

How much can soils heave?  It depends.  I once lived in a townhouse in Saint Louis Park with a patio that would heave about 4” during the winter; it got so bad that I could barely open my storm door during the winter.

Damage Caused by Frost Heave

Without a doubt, some of the worst frost heave I've come across has been here in Maple Grove. The photo below shows a Maple Grove deck that we recently inspected in the middle of an April snow storm. The right side had obviously heaved several inches. Click on the photo for a larger view.

Frost Heave at Deck

The deck shown below had severe frost heave in the middle and against the house, and had to be completely torn down and rebuilt because the deck was so severely heaved in the middle.

Frost Heave at Deck 2

Here's one more photo showing major frost heave at a deck.

Frost heave at deck 3

How Deck Footings Heave

When a deck is attached to a building, the part of the deck that gets supported by the earth needs to have proper frost footings. The most common deck footing is basically a big chunk of concrete poured in to a hole in the earth. The goal is to have this chunk of concrete go deep enough in to the ground so that the bottom rests on soils that never freeze, which should prevent the soils from pushing the footing up.

When deck footings aren't poured deep enough, decks can heave. Sandy, well drained soils aren't particular susceptible to frost heave, while soils with higher clay content are prone to frost heave. This is why it’s so important for deck footings to extend down below the frost line.

Preventing Frost Heave

How deep do footings need to be to prevent frost heave? There’s no magic number. When there is a lot of snow on the ground, the snow acts like a layer of insulation and reduces the frost depth. When it’s a winter with very little snow, like the type Minnesota experienced in 2011-2012, the frost depth will be much deeper than usual. Outdoor temperatures obviously make a difference, and so does proximity to water. Decks constructed near wetlands will have an increased potential for frost heave.

The Minnesota State Building Code requires footings to be a minimum of 42” deep in the southern part of the state, and a minimum of 60” deep in the northern part of the state. The diagram below shows the dividing line.

Frost depth map for Minnesota

While footings need to be deep enough in the soil to prevent frost heave, the depth of the footing is only one part of the equation. No matter how deep the footing is, if the surrounding soils expand enough to ‘grab on’ to the concrete footing, the surrounding soils can pull footings up out of the ground.

One step that can be taken to help prevent soils from grabbing on to the footing is to use waxed cardboard tubes for the footings, often referred to as sonotubes. The Family Handyman web site has a great cutaway photo of a footing with one of these tubes, used with permission below.

Deck footing cutaway view

Another step to prevent heaved footings is to ‘bell’ out the bottom of the footing, as shown in the photo above. The ‘bell’ shape at the bottom prevents soils from pushing the footing up and out, but it can also lead to a fractured footing. When expansive soils grab on to the walls of a footing and pull it up, the bell at the bottom will hold the footing in place until the pressure exerted by the frost exceeds the tensile strength of the concrete. Once that happens, the footing will simply break in half.

When you consider the relatively low tensile strength of concrete and the tremendous amount of force exerted by frost, it’s easy to understand how pier footings can break. One step that can be taken to help prevent this is to use rebar inside the footings. The diagram below, courtesy of the City of Maple Grove, shows a deck footing with rebar embedded to help prevent the footing from breaking.

Rebar embedded in footing

Next week I’ll have a follow-up post on a newer style of footing for decks that might just be the next big thing.

Reuben Saltzman, Structure Tech Home Inspections

        

Comment balloon 14 commentsReuben Saltzman • June 06 2013 02:51AM

Comments

Good stuff, thanks for sharing.

Posted by Joshua Frederick, Home Inspector in Defiance & all of Northwest Ohio (Home Inspector for ASPEC Residential Services, LLC) over 5 years ago

Good Morning: This is some great Info for all living in the cold country!! Keep the Info coming and good luck with your business,  E

Posted by Ed & Tracy Oliva, The Oliva Team Arizona Agents (West USA Realty - Arizona) over 5 years ago

Thanks Josh!

Ed & Tracy - you're lucky you don't need to worry about this stuff :)

Posted by Reuben Saltzman, Delivering the Unbiased Truth. (Structure Tech Home Inspections) over 5 years ago

Reuben, when I built my deck the code called for digging the footings 42 inches deep. Here in Northern Virginia we don't have the Winter's that you do in Minnesota.

Posted by Michael Setunsky, Your Commercial Real Estate Link to Northern VA over 5 years ago

Hi Reuben,

Excellent post on frost heave. There is very little of that here in lower New Mexico. But it can be really cold in the winter with temps getting below zero for weeks.

Have a great day in Minnesota.

Best, Clint McKie

Posted by Clint Mckie, Desert Sun Home, Comm. Inspection 1-575-706-5586 (Desert Sun Home, commercial Inspections) over 5 years ago

I knew how to prevent it right a way, but I had no idea of just how far down the earth actually can freeze in Minnesota.  Wow.  Over here near Seattle the earth remains about 55 degrees year around ad a depth of about 5 feet.  Perhaps,  in the mountains it extends much deeper.

Posted by Roger Stensland, Let's Move! (The Cascade Team Real Estate) over 5 years ago

Reuben, frozen dirt can be very strong---I bet you don't see too many of those "carryem' home in your car" support piers :)

Posted by Charles Buell, Seattle Home Inspector (Charles Buell Inspections Inc.) over 5 years ago

Good info Reuben!

Posted by Suzanne Otto, Your Montgomery County PA home stager (Six Twenty Designs) over 5 years ago

Wow, good info. Not knowing what you are doing can cause extensive future problems.

Posted by Lyn Sims, Schaumburg IL Real Estate (RE/MAX Suburban) over 5 years ago

Being born and raised in Michigan I understand the frost heave issue.  No living in SC, it is something we don't even think about!  Many clients from a northern climate are amazed at the lack of frost line.

 

Posted by Kim Peasley-Parker (AgentOwned Realty, Heritage Group, Inc.) over 5 years ago

Here the recommended depth is 24".  But I have a better solution.

Your problem is the cold.  Simply move the deck to a warmer climate and it won't heave as much.

Thanks.

Posted by Jay Markanich, Home Inspector - servicing all Northern Virginia (Jay Markanich Real Estate Inspections, LLC) over 5 years ago

You gotta go below the frost line.

The Minnesota State Building Code requires footings to be a minimum of 42” deep in the southern part of the state, and a minimum of 60” deep in the northern part of the state. The diagram below shows the dividing line.

that is why we have building codes.

Posted by David Popoff, Realtor®,SRS, Green ~ Fairfield County, Ct (DMK Real Estate ) over 5 years ago

As always, a nice article Reuben. Here we call that 'grabbing' adhesion.

Posted by Robert Butler, Montreal Home Inspector | Aspect Inspection (Aspect Inspection) over 4 years ago

I like reading a post that can make men and women think. Also, thank you for permitting me to comment!

imo for pc